ptp: netc: fix period truncation and potential divide-by-zero in PEROUT

Published Sep 17, 2026

Description

The max_period bound in net_timer_enable_perout() was computed as:

max_period = (u64)NETC_TMR_DEFAULT_FIPER + integral_period;

which exceeds U32_MAX when integral_period > 0 (e.g. 0x100000002 for the default 333333333 Hz clock). A period_ns that passes this check but exceeds U32_MAX is then silently truncated when stored into the u32 struct netc_pp::period field.

A truncated value of zero can reach netc_timer_set_perout_alarm(), where the local u32 period variable would also be 0, causing a divide-by-zero in roundup_u64(delta, period) whenever the stime < min_time branch is taken (which always happens for a start time of {0, 0}).

Additionally, netc_timer_enable_periodic_pulse() and netc_timer_enable_fiper() both compute:

fiper = pp->period - integral_period;

A zero pp->period results in an unsigned wraparound to 0xFFFFFFFD, mis-programming the FIPER hardware register.

Fix all three issues by capping max_period at NETC_TMR_DEFAULT_FIPER (0xFFFFFFFF). This ensures that any period_ns passing the range check fits in a u32 without truncation, so the stored value is always valid and non-zero. The accepted range is reduced by integral_period ns (typically only a few nanoseconds), which is negligible in practice.

Affected products

Remediation

No remediation recorded yet.

Metrics

Weaknesses (0)

No CWE recorded.

References (3)

Change history (0)

No recorded changes yet.

Sources
CVE.org / MITRE
Status PUBLISHED
Assigner Linux
Published Sep 17, 2026
Updated Sep 17, 2026
Reserved Sep 11, 2026
NVD
Status Received
Modified Sep 17, 2026
Red Hat
Severity n/a
Public date n/a