Cisco Industrial Ethernet 1000 Series Switches Denial of Service Vulnerability
Published Aug 19, 2026
5.3
MEDIUMCVSS 3.1
EPSS 0.51%
Description
A vulnerability in the handling of management plane packets by Cisco Industrial Ethernet (IE) 1000 Series Switches could allow an unauthenticated, remote attacker to cause the device manager, SSH, or API to become inaccessible.This vulnerability is due to insufficient protection against management plane flooding attacks. An attacker could exploit this vulnerability by sending a high rate of ICMP, SSH, or HTTP traffic to an affected device. A successful exploit could allow the attacker to cause the CPU of the device to increase, resulting in a denial of service (DoS) condition on the device manager web GUI, SSH, or API. Data traffic through the device is not affected.
Affected products
-
- Version 1.1StatusaffectedConstraints-
- Version 1.2StatusaffectedConstraints-
- Version 1.3StatusaffectedConstraints-
- Version 1.6StatusaffectedConstraints-
- Version 1.7.0StatusaffectedConstraints-
- Version 1.8.0StatusaffectedConstraints-
- Version 1.8.1StatusaffectedConstraints-
- Version 1.8.2StatusaffectedConstraints-
- Version 1.9.1StatusaffectedConstraints-
- Version 1.9.2StatusaffectedConstraints-
- Version 1.9.2aStatusaffectedConstraints-
- Version 1.9.3StatusaffectedConstraints-
- Version 1.9.4StatusaffectedConstraints-
- Version 1.9.5StatusaffectedConstraints-
- Version
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | |||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cisco | Cisco Industrial Ethernet Switches | n/a |
|
No data.
No data.
No Red Hat product state for this CVE.
No package ranges for this CVE.
Remediation
No remediation recorded yet.
References (2)
Change history (0)