A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (All versions), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (All versions >= V4.2.0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (All versions), SIMATIC ET 200SP IM 155-6 PN HA (incl
Published Jan 13, 2026
8.7
HIGHCVSS 4.0
EPSS 0.44%
Description
A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (All versions), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (All versions >= V4.2.0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (All versions), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (All versions < V1.3), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (All versions < V6.0.1), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (All versions >= V4.2.0 < V4.2.5), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (All versions < V4.2.2), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (All versions), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (All versions < V6.0.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (All versions >= V4.2.0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (All versions < V6.0.0). Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state. This could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation.
Affected products
-
- Version 0StatusaffectedConstraints<*
- Version
-
- Version V4.2.0StatusaffectedConstraints<*
- Version
-
- Version 0StatusaffectedConstraints<*
- Version
-
- Version 0StatusaffectedConstraints<V1.3
- Version
-
- Version 0StatusaffectedConstraints<V6.0.1
- Version
-
- Version V4.2.0StatusaffectedConstraints<V4.2.5
- Version
-
- Version 0StatusaffectedConstraints<V4.2.2
- Version
-
- Version 0StatusaffectedConstraints<*
- Version
-
- Version 0StatusaffectedConstraints<V6.0.0
- Version
-
- Version V4.2.0StatusaffectedConstraints<*
- Version
-
- Version V4.2.0StatusaffectedConstraints<*
- Version
-
- Version V4.2.0StatusaffectedConstraints<V4.2.5
- Version
-
- Version V4.2.0StatusaffectedConstraints<V4.2.5
- Version
-
- Version V4.2.0StatusaffectedConstraints<V4.2.5
- Version
-
- Version 0StatusaffectedConstraints<V6.0.0
- Version
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Simatic ET 200al IM 157-1 PN | n/a |
| ||||||
| Siemens | Simatic ET 200mp IM 155-5 PN HF | n/a |
| ||||||
| Siemens | Simatic ET 200sp IM 155-6 MF HF | n/a |
| ||||||
| Siemens | SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) | n/a |
| ||||||
| Siemens | Simatic ET 200sp IM 155-6 PN R1 | n/a |
| ||||||
| Siemens | Simatic ET 200sp IM 155-6 Pn/2 HF | n/a |
| ||||||
| Siemens | Simatic ET 200sp IM 155-6 Pn/3 HF | n/a |
| ||||||
| Siemens | SIMATIC PN/MF Coupler | n/a |
| ||||||
| Siemens | SIMATIC PN/PN Coupler | n/a |
| ||||||
| Siemens | Siplus ET 200mp IM 155-5 PN HF | n/a |
| ||||||
| Siemens | Siplus ET 200mp IM 155-5 PN HF T1 Rail | n/a |
| ||||||
| Siemens | Siplus ET 200sp IM 155-6 PN HF | n/a |
| ||||||
| Siemens | Siplus ET 200sp IM 155-6 PN HF T1 Rail | n/a |
| ||||||
| Siemens | Siplus ET 200sp IM 155-6 PN HF TX Rail | n/a |
| ||||||
| Siemens | SIPLUS NET PN/PN Coupler | n/a |
|
No data.
No data.
No Red Hat product state for this CVE.
No package ranges for this CVE.
Remediation
No remediation recorded yet.
References (1)
Change history (0)