Back

HIGH

Password recovery vulnerability in SICK SIM2x00 (ARM) Partnumber 1092673 and 1081902 with firmware version < 1.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method

Published Nov 1, 2022

Description

Password recovery vulnerability in SICK SIM2x00 (ARM) Partnumber 1092673 and 1081902 with firmware version < 1.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.2.0 as soon as possible (available in SICK Support Portal).

Affected products

Remediation

No remediation recorded yet.

References (2)

Change history (0)

No recorded changes yet.

Sources

CVE.org / MITRE

Status PUBLISHED
Assigner SICK AG
Published Nov 1, 2022
Updated May 5, 2025
Reserved Oct 28, 2022

CISA Vulnrichment

Updated May 5, 2025

NVD

Status Modified
Modified Jun 17, 2026

Red Hat

No data

ENISA EUVD

Assigner SICK AG
Published Nov 1, 2022
Updated May 5, 2025

GitHub