Back

HIGH

Barco wePresent WiPG-1600W devices have Improper Access Control

Published Nov 24, 2020

Description

Barco wePresent WiPG-1600W devices have Improper Access Control. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W device has an SSH daemon included in the firmware image. By default, the SSH daemon is disabled and does not start at system boot. The system initialization scripts read a device configuration file variable to see if the SSH daemon should be started. The web interface does not provide a visible capability to alter this configuration file variable. However, a malicious actor can include this variable in a POST such that the SSH daemon will be started when the device boots.

Affected products

Remediation

No remediation recorded yet.

Metrics

Weaknesses (0)

No CWE recorded.

References (2)

Change history (0)

No recorded changes yet.

Sources
CVE.org / MITRE
Status PUBLISHED
Assigner mitre
Published Nov 24, 2020
Updated Aug 4, 2024
Reserved Nov 6, 2020
NVD
Status Modified
Modified Jun 17, 2026
Red Hat
Severity n/a
Public date n/a