A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions)
Published May 14, 2019
5.4
MEDIUMCVSS 3.0
EPSS 0.88%
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.
Affected products
-
- Version All versionsStatusaffectedConstraints-
- Version
-
- Version All versions < V15.1 Update 1StatusaffectedConstraints-
- Version
-
- Version All versions < V15.1 Update 1StatusaffectedConstraints-
- Version
- Vendor Siemens AG Product SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F Defaultn/a
- Version All versions < V15.1 Update 1StatusaffectedConstraints-
- Version
-
- Version All versions < V15.1 Update 1StatusaffectedConstraints-
- Version
-
- Version All versions < V15.1 Update 1StatusaffectedConstraints-
- Version
-
- Version All versions < V15.1 Update 1StatusaffectedConstraints-
- Version
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens AG | SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) | n/a |
| ||||||
| Siemens AG | SIMATIC HMI Comfort Outdoor Panels 7" & 15" | n/a |
| ||||||
| Siemens AG | SIMATIC HMI Comfort Panels 4" - 22" | n/a |
| ||||||
| Siemens AG | SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F | n/a |
| ||||||
| Siemens AG | SIMATIC WinCC (TIA Portal) | n/a |
| ||||||
| Siemens AG | SIMATIC WinCC Runtime Advanced | n/a |
| ||||||
| Siemens AG | SIMATIC WinCC Runtime Professional | n/a |
|
Configuration 1
- < 15.1
Running on/with
- n/a
Configuration 2
- < 15.1
Running on/with
- n/a
Configuration 3
Running on/with
- n/a
Configuration 4
- < 15.1
Running on/with
- n/a
Configuration 5
Running on/with
- n/a
Configuration 6
- < 15.1
Running on/with
- n/a
Configuration 7
Running on/with
- n/a
Configuration 8
- < 15.1
- < 15.1
- < 15.1
Configuration 9
- n/a
Running on/with
- n/a
Configuration 10
- n/a
Running on/with
- n/a
Configuration 11
- n/a
Running on/with
- n/a
No data.
No Red Hat product state for this CVE.
No package ranges for this CVE.
Remediation
No remediation recorded yet.
References (3)
- http://www.securityfocus.com/bid/108412 vdb-entryx_refsource_BID
- https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf x_refsource_MISCVendor Advisory
- https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 x_refsource_MISC
| Link | Providers | Tags |
|---|---|---|
| http://www.securityfocus.com/bid/108412 | vdb-entryx_refsource_BID | |
| https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | x_refsource_MISCVendor Advisory | |
| https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Change history (0)
No recorded changes yet.