A vulnerability in Cisco NX-OS System Software running on Cisco MDS Multilayer Director Switches, Cisco Nexus 7000 Series Switches, and Cisco Nexus 7700 Series Switches could allow an authenticated, local attacker to access the Bash shell of an affected device's operating system, even if the Bash shell is disabled on the system

Published Nov 30, 2017

Description

A vulnerability in Cisco NX-OS System Software running on Cisco MDS Multilayer Director Switches, Cisco Nexus 7000 Series Switches, and Cisco Nexus 7700 Series Switches could allow an authenticated, local attacker to access the Bash shell of an affected device's operating system, even if the Bash shell is disabled on the system. The vulnerability is due to insufficient sanitization of user-supplied parameters that are passed to certain functions of the Python scripting sandbox of the affected system. An attacker could exploit this vulnerability to escape the scripting sandbox and enter the Bash shell of the operating system with the privileges of the authenticated user for the affected system. To exploit this vulnerability, the attacker must have local access to the affected system and be authenticated to the affected system with administrative or Python execution privileges. Cisco Bug IDs: CSCvd86513.

Affected products

Remediation

No remediation recorded yet.

Metrics

Weaknesses (2)

References (2)

Change history (0)

No recorded changes yet.

Sources
CVE.org / MITRE
Status PUBLISHED
Assigner cisco
Published Nov 30, 2017
Updated Aug 5, 2024
Reserved Aug 3, 2017
NVD
Status Modified
Modified Jun 17, 2026
Red Hat
Severity n/a
Public date n/a