Omron NS Series HMI Improper Neutralization of Input During Web Page Generation
Published Jul 24, 2014
4.0
MEDIUMCVSS 2.0
EPSS 1.36%
Description
Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.
Affected products
-
- Version 8.1xxStatusaffectedConstraints<8.68x
- Version
-
- Version 8.1xxStatusaffectedConstraints<8.68x
- Version
-
- Version 8.1xxStatusaffectedConstraints<8.68x
- Version
-
- Version 8.1xxStatusaffectedConstraints<8.68x
- Version
-
- Version 8.1xxStatusaffectedConstraints<8.68x
- Version
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Omron | NS10 | unaffected |
| ||||||
| Omron | NS12 | unaffected |
| ||||||
| Omron | NS15 | unaffected |
| ||||||
| Omron | NS5 | unaffected |
| ||||||
| Omron | NS8 | unaffected |
|
- 8.1
- 8.68
- n/a
- n/a
- n/a
- n/a
- n/a
No data.
No Red Hat product state for this CVE.
No package ranges for this CVE.
Remediation
Vendor solution
Omron Corporation has produced update, Version 8.69x for Japan and Version 8.7x for other countries, that mitigates the identified vulnerabilities. The updates for the NS series of HMI terminals can be downloaded at the following locations:
NS15 Software Update Version 8.7:
http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html
NS12 Software Update Version 8.7:
http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html
NS10 Software Update Version 8.7:
http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html
NS8 Software Update Version 8.7:
http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html
NS5 Software Update Version 8.7:
http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html
Metrics
No CVSS v4.0 score for this CVE.
No CVSS v3.1 score for this CVE.
No CVSS v3.0 score for this CVE.
AV:N/AC:M/Au:S/C:N/I:P/A:N
1 other source (CVE.org) ▾
AV:N/AC:L/Au:S/C:N/I:P/A:N
This CVE is not in the KEV list.
No CISA SSVC assessment for this CVE yet.
Estimated probability of exploitation in the wild in the next 30 days (FIRST EPSS). As of Oct 1, 2026.
Score over time
2022–2026- EPSS v2
- EPSS v3
- EPSS v4
- EPSS v5
Percentile over time
- EPSS v2
- EPSS v3
- EPSS v4
- EPSS v5
Table of values (11 key points)
Flat stretches are collapsed; showing up to 120 newest points.
| Date | Score | Percentile | Model |
|---|---|---|---|
| Oct 1, 2026 | 1.36% (0.01362) | 70.76th | v5 (v2026.06.15) |
| Jun 15, 2026 | 1.36% (0.01362) | 68.06th | v5 (v2026.06.15) |
| Mar 17, 2025 | 0.40% (0.00398) | 58.50th | v4 (v2025.03.14) |
| Dec 12, 2024 | 0.08% (0.00080) | 36.18th | v3 (v2023.03.01) |
| Jun 22, 2024 | 0.08% (0.00080) | 34.54th | v3 (v2023.03.01) |
| Jun 5, 2024 | 0.08% (0.00080) | 32.52th | v3 (v2023.03.01) |
| Mar 7, 2023 | 0.10% (0.00098) | 39.32th | v3 (v2023.03.01) |
| Mar 6, 2023 | 1.05% (0.01055) | 52.13th | v2 (v2022.01.01) |
| Sep 17, 2022 | 1.05% (0.01055) | 50.47th | v2 (v2022.01.01) |
| Apr 1, 2022 | 1.05% (0.01055) | 48.43th | v2 (v2022.01.01) |
| Feb 4, 2022 | 1.05% (0.01055) | 27.52th | v2 (v2022.01.01) |
References (4)
- http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01 Third Party AdvisoryUS Government Resource
- http://www.securityfocus.com/bid/68836
- https://automation.omron.com/en/us/products/
- https://www.cisa.gov/news-events/ics-advisories/icsa-14-203-01
| Link | Providers | Tags |
|---|---|---|
| http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01 | Third Party AdvisoryUS Government Resource | |
| http://www.securityfocus.com/bid/68836 | ||
| https://automation.omron.com/en/us/products/ | ||
| https://www.cisa.gov/news-events/ics-advisories/icsa-14-203-01 |
Change history (0)